Standards

UMDNS Names Tables,Operating-13961 , Operating Tables,Spinal-23732 , Operating table,multi-Specialty-25217 , Operating Tabletops -25215
Clinical Applications in General for the Operating Table Most operating tables are divided into three or more hinged sections. The principal divisions are the head, body, and foot sections. The head section can be ­removed and replaced by headrests (for use in cranial and eye surgery). The foot section can also be moved or removed for certain procedures (e.g., cystoscopy, endourology, urology, gynecology). Extensions can be added to the foot section to accommodate tall patients. In some models, the head and foot sections are interchangeable so that the patient can be reversed for extended radiographic imaging or special procedures
Conformity to Standards European CE (with 4 digit notified number)
Confirmity to standard for for electrical safety latest amendment IEC- 60601-2-40 or BIS Equivalent
Confirmity to Manufacturing Standards ISO 9001 & 13485 or ICMED 9001 & 13485

Table Features

Type of OT table Actuator Electrical
Type of mechanism for functioning or controlling the table movements Remote & Table mounted
Remote controlled positions Trendelenburg / reverse Trendelenburg, lateral tilt,longitudinalshift, height adjustment, antiflex and flex position and back plate up / down
Number of section provided in Table top Upto 6 sections
C-Arm Compatible Yes
Range of Table top length 1900 mm-2100 mm
Range of Table top width 500 mm-580 mm
Range of Table top Height 635 mm to 1035 mm
Material 304 Grade SS
Table top shall be X-ray compactable and stain Resistant Yes
Table Mattress Material 2 inch latex free fully radiolucent, detachable, impermeable to fluid and easily washable
Mattress material shall be in parts as per table top Yes
Provision of X ray cassette channel No

Table Positions

Trendelenburg Angle, Range 25⁰ to 30⁰
Reverse Trendelenburg Angle, Range 25⁰ to 30⁰
Lateral Tilt Angle (Left), Range 18⁰ to 25⁰
Lateral Tilt Angle (Right), Range 18⁰ to 25⁰
Head Section UP/Down Angle, Range upto 45⁰ to 90⁰
Back Section UP/Down Angle, Range upto 90⁰ to 30⁰
Horizontal Positioning, Range 0⁰ to 90⁰
Leg Section UP/Down, Range 20⁰-90⁰
Flex upto 230⁰
Reflex upto 100⁰
Table top longitudinal sliding, Range 5″ to 12″
Patient Weight Capacity 150-270 Kgs
Kidney Bridge required Yes
Detachable Head,Leg & Pelvic Section Yes
Split leg section , detachable-1 pair No
Quick Switch for Zero position Yes
Battery backup provided No
Battery backup of operating table in hrs Not provided
Foot Pump No
Both arm board should have up and down and rotation function Yes
Operating table should have foot brake for ease of use Yes

Description

Standards

UMDNS Names Tables,Operating-13961 , Operating Tables,Spinal-23732 , Operating table,multi-Specialty-25217 , Operating Tabletops -25215
Clinical Applications in General for the Operating Table Most operating tables are divided into three or more hinged sections. The principal divisions are the head, body, and foot sections. The head section can be ­removed and replaced by headrests (for use in cranial and eye surgery). The foot section can also be moved or removed for certain procedures (e.g., cystoscopy, endourology, urology, gynecology). Extensions can be added to the foot section to accommodate tall patients. In some models, the head and foot sections are interchangeable so that the patient can be reversed for extended radiographic imaging or special procedures
Conformity to Standards European CE (with 4 digit notified number)
Confirmity to standard for for electrical safety latest amendment IEC- 60601-2-40 or BIS Equivalent
Confirmity to Manufacturing Standards ISO 9001 & 13485 or ICMED 9001 & 13485

Table Features

Type of OT table Actuator Electrical
Type of mechanism for functioning or controlling the table movements Remote & Table mounted
Remote controlled positions Trendelenburg / reverse Trendelenburg, lateral tilt,longitudinalshift, height adjustment, antiflex and flex position and back plate up / down
Number of section provided in Table top Upto 6 sections
C-Arm Compatible Yes
Range of Table top length 1900 mm-2100 mm
Range of Table top width 500 mm-580 mm
Range of Table top Height 635 mm to 1035 mm
Material 304 Grade SS
Table top shall be X-ray compactable and stain Resistant Yes
Table Mattress Material 2 inch latex free fully radiolucent, detachable, impermeable to fluid and easily washable
Mattress material shall be in parts as per table top Yes
Provision of X ray cassette channel No

Table Positions

Trendelenburg Angle, Range 25⁰ to 30⁰
Reverse Trendelenburg Angle, Range 25⁰ to 30⁰
Lateral Tilt Angle (Left), Range 18⁰ to 25⁰
Lateral Tilt Angle (Right), Range 18⁰ to 25⁰
Head Section UP/Down Angle, Range upto 45⁰ to 90⁰
Back Section UP/Down Angle, Range upto 90⁰ to 30⁰
Horizontal Positioning, Range 0⁰ to 90⁰
Leg Section UP/Down, Range 20⁰-90⁰
Flex upto 230⁰
Reflex upto 100⁰
Table top longitudinal sliding, Range 5″ to 12″
Patient Weight Capacity 150-270 Kgs
Kidney Bridge required Yes
Detachable Head,Leg & Pelvic Section Yes
Split leg section , detachable-1 pair No
Quick Switch for Zero position Yes
Battery backup provided No
Battery backup of operating table in hrs Not provided
Foot Pump No
Both arm board should have up and down and rotation function Yes
Operating table should have foot brake for ease of use Yes

Standards Accessories

Number of Anesthetic Screen with side clamp & lock 1
Number of Arm rest with side clamp & lock 1 pair
Number of Shoulder support with side clamp & lock 1 pair
number of Leg support or Lithothomy with side clamp & lock 1 pair
Number of Extension bar 1 pair
Number of Horizontal Attachments 1
Bariatric table Extensions-Only for Bariatric Procedures-2 Inch Full set No
Bariatric table Extensions-Only for Bariatric Procedures-4 Inch Full set No
Radial setting clamp – 1 pair Yes
Restraint body strap-1pair Yes
Foot Support-1 no Yes
Bolster Pillow-1no Yes
Remote-1 no Yes
IV pole and Bracket Yes

Power Requirements

Power input to be 220-240V AC, 50Hz as appropriate fitted with Indian plug Single phase 220-240 Volt, 50 Hz ( AC Supply )

Reports

Warranty in years 3
User/Technical/Maintenance manuals to be supplied in English in hard and soft copy Yes
Demonstration of equipment and training to be provided after completing supplies & Installation before acceptance Yes
The Principal Manufacturer must have direct Presence/approved service center In India Yes
Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes
Attach certificate from the principal that spare parts will be available for next 10 years Yes
QA, QC and other tests(6 months/ 1 year as per NABH/JCI) Yes